SYD-4508A

Petroleum Asphaltum DuctilityTester

 Purpose:

    This instrument is suitable to the standards of GB/T4508,  T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

  Technical Parameters:

  Measure Range: 1.5m

  Temperature Control Range: room temperature ¡« 50¡æ

  Temperature Control Accuracy: ¡À0.5¡æ

  Testing Accuracy: ¡À1mm

  Speed: 50¡À2.5mm/min

  Temperature and ductility are controlled by computer. Computer-controlled data processing. Digital displays.

SYD-4508B

Petroleum Asphaltum DuctilityTester

 Purpose:

    This instrument is suitable to the standards of GB/T4508, T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

  Technical Parameters:

  Measure Range: 2.0m

  Temperature Control Range: room temperature ¡« 50¡æ

  Temperature Control Accuracy: ¡À0.5¡æ

  Testing Accuracy: ¡À1mm

  Speed: 50¡À2.5mm/min

  Temperature and ductility are controlled by computer. Computer-controlled data processing. Digital displays.

SYD-4508C

Low Temperature Asphaltum DuctilityTester

 Purpose:

    This instrument is suitable to the standards of GB/T4508,  T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

  Technical Parameters:

  Measure Range: 1.5m

  Temperature Control Range: 5 ¡« 50¡æ (adjustable)

  Temperature Control Accuracy: ¡À0.5¡æ

  Measure Accuracy: ¡À1mm

  Elongate Speed: 10-50mm/min adjustable

  Compressor refrigeration. Alteration temperature of stainless steel flume and extensibility are controlled by computer. Computer-controlled data dealing. Digital displays.

SYD-4508D

Low Temperature Asphaltum DuctilityTester

¡¡

Purpose:

¡¡

    This instrument is suitable to the standards of GB/T4508,  T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

¡¡

Technical Parameters:

¡¡

  Measure Range: 2.0m

  Temperature Control Range: 5 ¡« 50¡æ (adjustable)

  Temperature Control Accuracy: ¡À0.5¡æ

  Measure Accuracy: ¡À1mm

  Elongate Speed: 10 ¡« 50mm/min

  Compressor refrigeration. Alteration temperature of stainless steel flume and extensibility are controlled by computer. Computer-controlled data dealing. Digital displays.

SYD-4508E

Low Temperature Asphaltum DuctilityTester

¡¡

Purpose:

   

    This instrument is suitable to the standards of GB/T4508, T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

    Technical Parameters:

  Measure Range: 1.5m

  Temperature Control Range: 5 ¡« 50¡æ

  Temperature Control Accuracy: ¡À0.5¡æ

  Measure Accuracy: ¡À1mm

  Elongate Speed: 10 ¡« 50mm/min

  Compressor refrigeration£º Temperature and extensibility are controlled by computer

  Computer-controlled data dealing£º Digital displays

  Stainless steel box, flume and transmission parts

  Marble board, frequency conversion timing.

SYD-4508F

Low Temperature Asphaltum DuctilityTester

 Purpose:

    This instrument is suitable to the standards of GB/T4508 and T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

  Technical Parameters:

  Measure Range: 2.0m

  Temperature Control Range: 5 ¡« 50¡æ (adjustable)

  Temperature Control Accuracy: ¡À0.5¡æ

  Measure Accuracy: ¡À1mm

  Elongate Speed: 10 ¡« 50mm/min (adjustable)

  Ductility Measuring Range: 0 ¡« 1000N

  Ductility Accuracy: ¡À5N

  Automatically show and print the ductility value, average value, maximum ductility and movement curve.

SYD-4508G

Low Temperature Asphaltum DuctilityTester

 Purpose:

    This instrument is suitable to the standards of GB/T4508, T0605. Test the length of asphaltum when asphaltum is drawn to break under certain temperature and speed.

Referrence standard: ASTMD113

  Technical Parameters:

  Measure Range: 2.0m

  Temperature Control Range: 5 ¡« 50¡æ (adjustable)

  Temperature Control Accuracy: ¡À0.1¡æ

  Measure Accuracy: ¡À1mm

  Elongate Speed: 10 ¡« 50mm/min (adjustable)

  Ductility Measuring Range: 0 ¡« 300N

  Ductility Accuracy: ¡À1N

  Automatically show and print the ductility value, average value, maximum ductility and movement curve.

¡¡